Brand: ABB
Model: RS 611 006-AA
Part No: SPAJ 140 C-AA
Describe: OVERCURRENT RELAY
Status: New/Used
Combined overcurrent & earth-fault relay type SPAJ 140 C
ABB SPAJ 140 C(RS 611 006-AA)
The combined overcurrent and earth-fault relay is a secondary relay to be connected to the current transformers of the protected object. The three-phase overcurrent unit and the earth-fault unit continuously measure the phase currents and the neutral current of the protected object. On detection of a fault the relay starts, trips the circuit breaker, initiates auto-reclosing, provides alarm, records fault data etc. in accordance with the application and the configured relay functions.
Many products have not been launched yet. If you need more products, please contact us
Email: [email protected]
SPAJ 140 C型过电流和接地故障组合继电器
设计与原理
过电流和接地故障组合继电器是连接到受保护对象的电流互感器的二次继电器。三相过电流单元和接地故障单元连续测量被保护对象的相电流和中性电流。检测到故障后,继电器根据应用和配置的继电器功能启动、跳闸断路器、启动自动重合闸、提供报警、记录故障数据等。
三相过电流保护为相间短路和过载故障提供定时(DT)和反定时最小时间(IDMT)操作特性。包括用于过载的低设置过电流阶段和用于严重短路的高设置瞬时阶段。支持单相、两相或三相保护配置,连接到二次电流互感器(1 A/5 CT输入)。
QQ:3699232536
接地故障(零序电流)保护集成接地故障保护装置,具有低设置和高设置阶段。定时和IDMT曲线都是可选的。专为牢固接地、电阻接地或阻抗接地中压配电网中的接地故障检测而设计,可检测中性点不平衡和接地漏电故障。
断路器故障保护(CBFP)内置断路器故障逻辑。如果断路器在收到跳闸命令后未能打开,继电器将向上游断路器发出备用跳闸信号,以隔离故障段并扩大故障清除范围。
购买咨询热线:18120742318





